The auto-on functionality allows the BIB to automatically connect the battery bank to the DC bus when certain conditions are met, such as the absence of alarms and sufficient state of charge (SoC)
The BIB includes several safety features, such as automatic disconnection in case of missing batteries, pre-charge circuits to prevent inrush currents and programmable SoC thresholds to prevent deep discharge
The BIB uses the CAN open protocol to communicate with batteries and other system components, allowing for integration into complex systems
Up to 16 batteries can be connected to the BIB without external CAN power. With the 12V BIB versions, external CAN power is always necessary
Collects the information from all Li-ion batteries in the battery bank, presenting it as one battery
The BIB is a standalone device, managing the connection and disconnection of the battery bank based on predefined conditions and battery statuses
Programmable power down on user-adjustable battery (bank) SoC level
Real time clock for accurate time-stamped function, statistics and error logging
Up to 100 Li-ion batteries can be connected to the BIB with the use of external CAN power
The BIB can be configured using a CAN-USB converter and the battery monitor software